Physical Dimensions & Weight:

  • Base Unit: 12.1”/309 mm (H) x 14.4”/365 mm (W) x 6.3”/159 mm (D)
  • Weight: 17.6 lbs/8.0 kgs (including anesthetic agents module and batteries)

Application:

  • Small, Medium, and Large animal

Performance Specifications:

  • Display: 15” color TFT, Resolution 1024 x 768
  • Trace: 8 waveforms
  • Indicators:
    • Alarm indicator
    • Power indicator
    • QRS beep and alarm sound
  • Trend time: 1 – 48 hours
  • Recorder:
    • Built-in, thermal array, 2 channels
    • Record width: 1.9”/48 mm
    • Recorder paper: 2”/50 mm
    • Record speed: 25 mm/s, 50 mm/s

ECG:

  • Input: 5-lead ECG cable and standard AAMI line for connection
  • Lead Choice: I, II, III, aVR, aVF, aVL, V, TEST
  • Gain Choice : x0.5, x1, x2, x4
  • Frequency Characteristic: 0.05 ~ 35 HZ (+3dB)
  • ECG Waveforms: 7 channels
  • Penetration Voltage: 4000VAC 50/60Hz
  • Sweep Speed: 12.5, 25 and 50 mm/s
  • HR Display Range: 30 – 300bpm
  • Accuracy: 1 bpm or 1%, whichever is greater
  • Alarm Limit Range Setting: Upper limit 100 – 200 bpm; Lower limit 30 – 100 bpm

RESP:

  • Measure Method: RA-LL impedance
  • Range: 0 – 120 rpm
  • Accuracy: 3 rpm
  • Alarm Limit Setting: Upper limit 6 – 120 rpm: Lower limit 3 – 120 rpm
  • Sweep Speed: 12.5 and 25 mm/s

TEMP:

  • Range: 25 – 50 (C)
  • Accuracy:
    • 0.2 C (25.0 – 34.9 C)
    • 0.1 C (35.0 – 39.9 C)
    • 0.2 C (40.0 – 44.9 C)
    • 0.3 C (45.0 – 50.0 C)
  • Display Resolution: 0.1 C
  • Alarm Limit Setting: Upper limit 0 – 50 C, lower limit 0 – 50 C
  • Channel: 2 channels

Masimo SET SpO2

  • Measuring Range:
    • SpO2: 1~100 %
    • PR: 25~20 %
  • SpO2 Accuracy (non-motion):
    • Adult Pediatric: 70~69%: unspecified
    • Neonate: 70~69 %: unspecified
  • SpO2 Accuracy (motion):
    • Adult Pediatric: 70~100 %: ±3 %, 0~100 %: ± 3 %, 0~240 bpm: ±3 bpm
  • PR Accuracy (motion):
    • Adult Pediatric Neonate: 25<span 20.8px;"="">~240 bpm: ±5 bpm
  • Low Perfusion Performance: >0.02 % Pulse Amplitude and % Transmission >5
    • SpO2: ±2 %
    • PR: ±3 bpm
  • Modes:
    • Averaging mode: 2,4,8,10,12,14 and 16 s
    • Sensitivity: Normal, APOD and Maximum

NIBP:

  • Measuring Technology: Automatic oscillating measurement
  • Cuff Inflating: <30s (0 – 300 mmHg, standard adult cuff)
  • Measuring Period: AVE<40s
  • Mode: Manual, Auto
  • Measuring Interval in AUTO Mode: 2 min – 4 hrs
  • Pulse Rate Range: 30 – 250 (bpm)
  • Measuring Range:
    • Adult/Pediatric Mode: SYS: 40 – 250 (mmHg) DIA :15 – 200 (mmHg)
    • Neonatal Mode: SYS: 40 – 135 (mmHg) DIA : 15 – 100 (mmHg)
  • Resolution: 1mmHg

Accuracy:

  • Maximum Mean error: 5mmHg
  • Maximum Standard deviation: 8mmHg
  • Overpressure Protection:
    • Adult Mode: 300(mmHg)
    • Neonatal Mode: 160 (mmHg)
  • Alarm Limit Setting:
    • SYS: 50 – 240 mmHg
    • DIA: 15 – 180 mmHg

IBP:

  • Measurement Range: -50 – 300mmHg
  • Channel: 2 channels
  • Pressure Transducer: Sensitivity, 5μV/V/mmHg
  • Impedance Range: 300 – 3000Ω
  • Transducer Sites: ART, PA,CVP, RAP, LAP, ICP
  • Unit: mmHg/kPa selectable
  • Resolution: 1 mmHg
  • Accuracy: 1 mmHg or 2%, whichever is greater
  • Alarm Range: -10 – 300 mmHg

EtCO2 (Respironics) (mainstream or sidestream):

  • CO2 Measurement Range: 0 – 99 mmHg

Accuracy:

  • 2 mmHg (0 – 38 mmHg)
  • 39-99 mmHg 5% of reading + 0.08% for every 1 mmHg (above 38 mmHg)
  • Sampling Rate: 50 ml/min
  • Initialization Time: 30 seconds (typical), reaches 5% steady-state accuracy within 3 minutes
  • Respiration Rate: 0 – 150 breaths/min
  • Mode: Adult, neonate

Anesthetic Agents:

  • Industry standard 802.11b/g wireless network

Power:

  • Source: External AC power or internal battery
  • AC Power: 100 – 240VAC, 50/60Hz, 150VA
  • Battery: Built-in and rechargeable
  • Charge Time: 4 hours

Environmental Specifications:

  • Operating Temperature: 5 – 40 C
  • Storage Temperature: -20 – 65 C
  • Operating Humidity: ≤80 %
  • Storage Humditiy: ≤80 %

Documents: