The Masimo Rad-57 is the world’s most versatile handheld oximeter with a rugged lightweight design ideal for field or hospital settings.
The Rad-57 requires no user calibration and does not need patient cooperation or consciousness. This is a great replacement for existing handheld pulse oximeters. You can get factory-ordered options or field-installed software upgrades to continuous monitoring and spot check measurements of SpHb, SpOC, SpMet and PVI.
Key Features:
- Helps clinicians reduce the risk of misdiagnosing unsuspected carbon monoxide poisoning
- Assists clinicians in detecting potentially life-threatening acquired methaemogloninaemia
- Accurate SpO2 and pulse rate measurements during the most difficult clinical conditions, including during patient motion and conditions of low peripheral perfusion motion
- Perfusion Index (PI) indicates arterial pulse signal strength and may be used by clinicians to help diagnose during low perfusion
- User may programme default power-up settings Delivers more than 8 hours of continuous monitoring of SpCO, SpMet, SpO2, Pulse Rate, and Perfusion Index
- FastSat tracks rapid changes in arterial O2 with unmatched fidelity
- SmartTone™ beeps in sync with pulse, even under patient motion conditions
- Up to 72 hours of trending memory of SpCO, SpMet, SpO2, Pulse Rate, and Perfusion Index
- Sensitivity options of APOD, Normal and MAX provide flexibilty to support a range of clinical applications
Technology
- More than 100 independent and objective studies demonstrate Masimo SET provides the most reliable oxygen saturation (SpO2) and pulse rate (PR) measurements under challenging clinical conditions, including patient motion and low peripheral perfusion.
- Masimo rainbow technology analyzes multiple wavelengths of light to measure.
- Masimo SET measurements, total hemoglobin (SpHb), carboxyhemoglobin (SpCO), methemoglobin (SpMet), and oxygen content (SpOC™).
- Pleth Variability Index (PVI) is a breakthrough measurement that may help clinicians noninvasively and continuously assess fluid status of patients.
SPECIFICATIONS
Trending
- Provides 72 hours of trending at 2 second resolution of SpO2, SpCO, SpMet, pulse rate, and perfusion index. Output to PC running Masimo TrendComTM Utility.
SPO2 Modes
- Averaging mode5 - 2, 4, 8, 10, 12, 14 or 16 seconds
- Sensitivity - APOD, Normal and Max
- FastSat 6 - On / Off
Alarms
- Audible and visual alarms for high and low saturation (SpO2 1% to 100%, SpCO 5% - 40%, SpMet 0.5% to 30%, and pulse rate 25 - 240 bpm) Sensor condition, system failure and low battery alarms
Display / Indicators
- Data Display - %SpO2, %SpCO, %SpMet, SpCO bar, SpMet bar, pulse rate, perfusion index, low Signal IQ alarm status, alarm silence and battery life
- Type - LED
Compliance
- EMC Compliance - EN60601-1-2, Class B
- Equipment Classification - IEC 60601-1-1
- Degree of Protection - Type BF-Applied part
Measurement Range
- SpO2 - 1% - 100%
- SpCO - 0% - 99%
- SpMet - 0% - 99.9%
- Pulse Rate - 25 - 240 (bpm)
- Perfusion Index - 0.02% - 20%
Oxygen Saturation Accuracy (%SpO2)
- Saturation - 70% to 100%
- No Motion
- Adults, Paediatrics - 2 digits
- Neonate - 3 digits
- Motion1
- Adults, Paediatrics - 3 digits
- Neonate - 3 digits
- Low Perfusion2
- Adults, Paediatrics - 2 digits
- Neonate - 3 digits
Carboxyhaemoglobin Saturation Accuracy (%SpCO)
- SpCO - 1% - 40% 3 digits3
Methaemoglobin Saturation Accuracy (%SpMet)
- SpMet - 1% - 15% 1 digits3
Pulse Rate Accuracy
- Pulse Rate - 25 - 240 bpm
- No Motion
- Adults, Paediatrics, Neonate - 3 digits
- Motion1
- Adults, Paediatrics, Neonate - 5 digits
- Low Perfusion2
- Adults, Paediatrics, Neonate - 3 digits
Resolution
- Oxygen Saturation (%SpO2) - 1%
- Pulse Rate (bpm) - 1 bpm
- Carboxyhaemoglobin Saturation (%SpCO)
- Numeric Display - 1%
- Bar Display - 3, 6, 9, 12, 15, 20, 25, 30, 35, > 40%
- Methaemoglobin Saturation (%SpMet)
- Numeric Display - 0.1%
- Bar Display - 0.5, 1-5, 7.5, 10, 15 > 20%